victaulic.
com40.
603123RevKUpdated02/20192019VictaulicCompany.
Allrightsreserved.
DryTypePendentsStandardandQuickResponseFlushSleeveandSkirtPlainBarrelIntermediateExtendedRecessed1.
0PRODUCTDESCRIPTIONModels:V3606andV3605Style:Pendent,RecessedPendentorIntermediateLevelPendentNominalOrificeSize:"/13mmK-Factor:5.
6Imp.
/8.
1S.
I.
1NominalThreadSize:1"NPT/25mmBSPTMax.
WorkingPressure:175psi/1207kPa/12barFactoryHydrostaticTest:100%@500psi/3447kPa/34barMin.
OperatingPressure:7psi/48kPa/.
5barTemperatureRating:Seetableinsection2.
01ForK-Factorwhenpressureismeasuredinbar,multiplyS.
I.
unitsby10.
0.
1SystemNo.
LocationSubmittedByDateSpecSectionParagraphApprovedDate40.
603123RevKUpdated02/20192019VictaulicCompany.
Allrightsreserved.
victaulic.
com2.
0CERTIFICATION/LISTINGSAPPROVALS/LISTINGSModelV3605V3605V3606V3606OrificeSize(inches)OrificeSize(mm)13131313NominalKFactorImperial5.
65.
65.
65.
6NominalKFactorS.
I.
28.
18.
18.
18.
1ResponseStandardStandardQuickQuickDeflectorTypePendentRecessedPendentPendentRecessedPendentApprovedTemperatureRatingsF°/C°cULus135°F/57°C155°F/68°C200°F/93°C286°F/141°C135°F/57°C155°F/68°C200°F/93°C286°F/141°C135°F/57°C155°F/68°C200°F/93°C286°F/141°C135°F/57°C155°F/68°C200°F/93°C286°F/141°CFM135°F/57°C155°F/68°C200°F/93°C286°F/141°C135°F/57°C155°F/68°C200°F/93°C135°F/57°C155°F/68°C200°F/93°C286°F/141°C135°F/57°C155°F/68°C200°F/93°CCCC155°F/68°C155°F/68°CNoneNone2ForK-FactorwhenpressureismeasuredinBar,multiplyS.
I.
unitsby10.
NOTEListingsandapprovalasofprinting.
TemperaturesarelistedforallhazardsandapprovedforV3605andV3606drysprinklersupto48"length.
CCCfapprovedforV3605drysprinklers107to1250mm/4.
2-49.
2"inlength.
2victaulic.
com40.
603123RevKUpdated02/20192019VictaulicCompany.
Allrightsreserved.
victaulic.
com3.
0SPECIFICATIONS–MATERIALDeflector:BrassorstainlesssteelBulb:GlasswithglycerinsolutionBulbNominalDiameter:Standard:5.
0mmQuickResponse:3.
0mmSplitSpacer:StainlesssteelLoadScrew:BrassPipCap:StainlesssteelSpringSealAssembly:Teflon3coatedBerylliumnickelalloyandstainlesssteelFrame:DiecastbrassOuterTube:GalvanizedsteelpipeInnerTube:StainlesssteelOrificeInsert:StainlesssteelEscutcheon/Plate:1010-1018mildsteelandstainlesssteelTorsionSpring:SSTWireInstallationWrench:ModelV36OpenEndandRecessedWrenchesfitallV36Seriesframes.
SprinklerFinishes:PlainbrassChromeplatedWhitepainted4,5Flatblackpainted4,5Custompainted4,5VC-25063TeflonisaregisteredtrademarkofDupontCo.
4NotavailableontheIntermediateLevelStylePendent.
5ULListedforcorrosionresistance.
6ULListedandFMApprovedforcorrosionresistance.
NOTEWeatherresistantescutcheonavailableuponrequest.
Forcabinetsandotheraccessoriesrefertoseparatesheet.
Exaggeratedforclarity3victaulic.
com40.
603123RevKUpdated02/20192019VictaulicCompany.
Allrightsreserved.
victaulic.
com4.
0DIMENSIONS1"NPT3"Dia.
2""FlushTeewithsameoutletsizeassprinklerthreadsize.
See"ImportantInstallationInformation",laterinthisdocument1"Min.
Dia.
HoleinCeiling"A"(Min.
1")1"NPT3"Dia.
2"Min.
4"Max.
SleeveandSkirtTeewithsameoutletsizeassprinklerthreadsize.
See"ImportantInstallationInformation",laterinthisdocument"A"(Min.
1")1"Min.
Dia.
HoleinCeilingTwoPieceEscutcheon1"NPT3"Dia.
1""IntermediateLevelPendentTeewithsameoutletsizeassprinklerthreadsize.
See"ImportantInstallationInformation",laterinthisdocument"A"(Min.
1")1"NPT1"PlainBarrelTeewithsameoutletsizeassprinklerthreadsize.
See"ImportantInstallationInformation",laterinthisdocument"A"(Min.
1")1"NPT3"Extended3"Min.
5"Max.
Teewithsameoutletsizeassprinklerthreadsize.
See"ImportantInstallationInformation",laterinthisdocument"A"(Min.
1")1"Min.
Dia.
HoleinCeilingTwoPieceEscutcheon1"NPT2"Dia.
CeilingCupCollarRecessed1"Min.
1"Max.
Teewithsameoutletsizeassprinklerthreadsize.
See"ImportantInstallationInformation",laterinthisdocument"A"(Min.
1")2"Min.
Dia.
HoleinCeilingNOTEThe"A"dimensionofadrysprinkler,whichextendsintoafreezerfromawetpipingsystem,musttakeintoaccountthewallorceilingthicknessofthefreezer.
SeeIMPORTANTINSTALLATIONINFORMATIONlaterinthisdocument.
4victaulic.
com40.
603123RevKUpdated02/20192019VictaulicCompany.
Allrightsreserved.
victaulic.
com5.
0PERFORMANCEContactVictaulicforperformancedetails.
6.
0NOTIFICATIONSWARNINGReadandunderstandallinstructionsbeforeattemptingtoinstallanyVictaulicproducts.
Alwaysverifythatthepipingsystemhasbeencompletelydepressurizedanddrainedimmediatelypriortoinstallation,removal,adjustment,ormaintenanceofanyVictaulicproducts.
Wearsafetyglasses,hardhat,andfootprotection.
Failuretofollowtheseinstructionscouldresultindeathorseriouspersonalinjuryandpropertydamage.
Theseproductsshallbeusedonlyinfireprotectionsystemsthataredesignedandinstalledinaccordancewithcurrent,applicableNationalFireProtectionAssociation(NFPA13,13D,13R,etc.
)standards,orequivalentstandards,andinaccordancewithapplicablebuildingandfirecodes.
Thesestandardsandcodescontainimportantinformationregardingprotectionofsystemsfromfreezingtemperatures,corrosion,mechanicaldamage,etc.
Theinstallershallunderstandtheuseofthisproductandwhyitwasspecifiedfortheparticularapplication.
Theinstallershallunderstandcommonindustrysafetystandardsandpotentialconsequencesofimproperproductinstallation.
Itisthesystemdesigner'sresponsibilitytoverifysuitabilityofmaterialsforusewiththeintendedfluidmediawithinthepipingsystemandexternalenvironment.
Thematerialspecifiershallevaluatetheeffectofchemicalcomposition,pHlevel,operatingtemperature,chloridelevel,oxygenlevel,andflowrateonmaterialstoconfirmsystemlifewillbeacceptablefortheintendedservice.
Failuretofollowinstallationrequirementsandlocalandnationalcodesandstandardscouldcompromisesystemintegrityorcausesystemfailure,resultingindeathorseriouspersonalinjuryandpropertydamage.
5victaulic.
com40.
603123RevKUpdated02/20192019VictaulicCompany.
Allrightsreserved.
victaulic.
com7.
0REFERENCEMATERIALSImportantInstallationInformation:Fordetailedinstallationinstructions,seepublicationI-40.
No.
1VictaulicModelV36SeriesDrysprinklersshouldbeinstalledinaccordancewithNFPA13.
Thesesprinklersaretobeinstalledusingapipewrenchappliedtotheoutertube.
Whenthisisnotpossible,thepropersprinklerwrenchmaybeusedwithextremecareforlengthsuptoapproximately18".
Excessiveforcemaydistorttheframethusdestroyingtheunit.
No.
2DrysprinklersMUSTbeinstalledonlyintotheoutletofacastormalleableirontee.
No.
3DONOTinstalldrysprinklersintoanycouplingsorthreadedelbows.
Inaddition,DONOTinstalldrysprinklersintoanyfittingthatinterfereswiththreadpenetration.
NOTE:TheendsealofthedrysprinklerMUSTNOTbottomoutinthefitting.
TYPICALSLEEVEANDSKIRTCONFIGURATIONFOREXAMPLEONLYDiameterofholeisdependentuponthetypeofescutcheonselected.
Spacemustbesealedtopreventcondensationfromforming,perNFPArequirements.
EndSealInsulationWallorCeilingofFreezer"A"SeeNote"C"ExposedMinimumBarrelLength(RefertoTable)"D"HEATEDSPACECOLDSPACENOTEThe"A"dimensionofadrysprinkler,whichextendsintoafreezerfromawetpipingsystem,musttakeintoaccountthewallorceilingthicknessofthefreezer.
Theminimumlengthofthedrysprinklershouldnotbelessthanthelengthsspecifiedinthefollowingtable,plusthethicknessofthefreezer'swallorceiling("A"="C"+"D").
Refertothedrawingforarepresentationofthe"A"dimension.
DONOTattempttomodifydrysprinklers,sincetheyaremanufacturedtothisspecific"A"dimension.
Thefollowingtableisusedwhentheambienttemperatureismaintainedbetween40°F/4°Cand60°F/16°Caroundthewetpipingsystem.
AmbientTemperatureExposedtoDischargeEndofSprinklerExposedMinimumBarrelLengthinches/mm°F°C40°F4°C50°F10°C60°F16°C40000400030-100000020400-71020010-1282031250001230-18305760-10-23143564102125-201463-2935615276-30-341640682034102-401884-40457203102-50-4620508102546152-6020106-515082541526victaulic.
com40.
603123RevKUpdated02/20192019VictaulicCompany.
Allrightsreserved.
victaulic.
com7.
0REFERENCEMATERIALS(CONTINUED)Ratings:Allglassbulbsareratedfortemperaturesfrom-67°F/-55°Ctothoseshowninthetablebelow.
TemperatureNominalTemperatureMaximumAmbientRatingTemperatureAllowedSprinklerTemperature°F°FClassification°C°CGlassBulbColorOrdinary135F100FOrange57C38COrdinary155F68C100F38CRedIntermediate200F150FGreen93C65CIntermediate286F141C225F107CBlueAvailableWrenches:ModelV36OpenEndandRecessedWrenchesfitallV36Seriesframes.
7.
1REFERENCEMATERIALS10.
65:VictaulicFireLockIGSInstallation-ReadyStyleV9SprinklerCoupling25.
14:VictaulicIGSGrooveSpecificationsI-V9:StyleV9VictaulicFireLockIGSInstallation-ReadySprinklerCouplingI-40:VictaulicFireLockAutomaticSprinklersInstallationandMaintenanceGuide7victaulic.
com
如果我们较早关注NameCheap商家的朋友应该记得前几年商家黑色星期五和网络星期一的时候大促采用的闪购活动,每一个小时轮番变化一次促销活动而且限量的。那时候会导致拥挤官网打不开迟缓的问题。从去年开始,包括今年,NameCheap商家比较直接的告诉你黑色星期五和网络星期一为期6天的活动。没有给你限量的活动,只有限时六天,这个是到11月29日。如果我们有需要新注册、转入域名的可以参加,优惠力度还是比...
易探云怎么样?易探云最早是主攻香港云服务器的品牌商家,由于之前香港云服务器性价比高、稳定性不错获得了不少用户的支持。易探云推出大量香港云服务器,采用BGP、CN2线路,机房有香港九龙、香港新界、香港沙田、香港葵湾等,香港1核1G低至18元/月,183.60元/年,老站长建站推荐香港2核4G5M+10G数据盘仅799元/年,性价比超强,关键是延迟全球为50ms左右,适合国内境外外贸行业网站等,如果需...
iON Cloud怎么样?iON Cloud今天发布了7月份优惠,使用优惠码:VC4VF8RHFL,新购指定型号VPS半年付或以上可享八五折!iON的云服务器包括美国洛杉矶、美国圣何塞(包含了优化线路、CN2 GIA线路)、新加坡(CN2 GIA线路、PCCW线路、移动CMI线路)这几个机房或者线路可供选择,有Linux和Windows系统之分,整体来说针对中国的优化是非常明显的,机器稳定可靠,比...
response.flush为你推荐
腾讯周鸿祎爱信艾达株式会社支持ipad支持ipad支持ipad支持ipad国家标准苹果5win10关闭445端口win10怎么关闭445的最新相关信息iexplore.exe应用程序错误iexplore.exe---应用程序错误.是什么意思?win7如何关闭445端口如何关闭445端口,禁用smb协议
免费cn域名注册 北京租服务器 smartvps 华为云服务 host1plus 谷歌香港 shopex空间 抢票工具 密码泄露 ftp免费空间 google台湾 东莞服务器托管 电信网络测速器 免费网络 lamp兄弟连 广州服务器托管 七十九刀 register.com 美国主机 发证机构 更多