PRODUCTOVERVIEWEISswitches,supportingbothtwisted-pairandfibreoptics,segmenttheEthernetnetworkintoseparatecollisiondomains.
Allmodelsfunctionasa"bridge"betweendatalinks,creatingalargernetworkdiameterandgreaterthroughputinindustrialapplicationsthanpossiblewithrepeatinghubs.
TheEISSeriesmeetsUL864andUL1604compliance.
Twomodels,theEIS8-100TandtheEIS6-100T/FT,qualifyasControlUnitAccessoriesforfire-protectivesignalingsystems(UL864).
TheseproductsalsoqualifyforuseinClassI,Division2,hazardouslocations(GroupsA,B,C,D),meetingUL1604regulatoryapproval.
ClassIhazardouslocationsarethosewherefireorexplosionhazardsmayexistduetothepresenceofflammablegases,vapors,orflammableliquids.
Eachswitchportautomaticallynegotiatesdatarate,duplex,andflowcontrol.
TheswitchlearnstheportlocationsofEthernetdevicesbyreadingcompleteEthernetframesandobservingsourceaddresses.
Theswitchthencreatesandmaintainsatableofsourceaddressesandcorrespondingportassignments.
Throughputisimprovedbyrestrictingtraffictoportsinvolvedinadataexchangeallowingsimultaneouspackettransfers.
Addresstableagingallowschangestofieldwiring.
Messagestounknowndestinationsarefloodedtoallportsasarebroadcastandmulticastframes.
TheseunitsaccommodateindustrialapplicationsrequiringafibrebackbonewithitsEIS5andEIS6models,makingthemidealforthoseapplicationswhereimmunitytoEMI/RFIandanetworkingdistanceupto15kmareimportant.
Thesebenefitsresultindecreaseddowntime,feweroutragesandimprovedreliability.
OnepowerLEDandoneloop-detectionLEDareprovided.
EachporthastwoLEDs:oneisgreenandoneisyellow.
ThegreenLEDglowsifalinkexistsandflashestoindicateactivity.
TheyellowLEDglowsifdataistransferringat100Mbps.
Eachunitacceptswide-range,low-voltageACorDCpower,designedwithbroadcaststormprotection;andredundantpowercanbeconnected.
Plug-and-Play(PnP)10BASE-T/100BASE-TX/100BASE-FXcompliantShieldedRJ-45connectorsorSC/ST-stylefibreopticconnectorsAuto-negotiateddatarateandflowcontrolontwisted-pairportsPoweredfromanunregulatedDCpowersource(10–36V)orfromanACpowersource(8–24V,47–63Hz).
Powerisprovidedthroughaquick-disconnectterminalstrip.
TD000500-0DIPage1EISSeriesDataSheetEISEthernetSwitchingHubsBroadcaststormcontrolMultimodeorsingle-modefibreFull-orhalf-duplexoperationontwisted-pairportsProvisionforredundantpowerconnectionsLEDsforlink/activity,datarate,powerandloopdetectionEasypanelorDIN-railinstallationIndustrialenvironmentEMCcompatibleUL508Listed,IndustrialControlEquipmentC-ULListed,CSA22.
2No.
14-M91,IndustrialControlEquipmentUL1604Listed,CSAStandardC22.
2No.
213-M1987,Non-IncentiveElectricalEquipmentforuseinClassI,Division2,HazardousLocations(GroupsA,B,C,D)UL864RecognizedComponentControlUnitsforFire-ProtectiveSignalingSystem(EIS8-100TandEIS6-100T/FTonly)CEMarkTD000500-0DIPage2MechanicalPowerDiagramsDataSheetEISSeriesDCPoweredACPoweredRedundantDCPoweredACPowered(groundedsecondary)ACPoweredwithBatteryBackupTD011201-0DGPage3MDI-X110BASE–T/100BASE-TXRJ-45Usage1TD+2TD–3RD+4NotUsed5NotUsed6RD–7NotUsed8NotUsed1Portsnormallyassumetheinternalcrossoverfunction,butwillautomaticallyadapttoconnecteddevices.
DataSheetEISSeriesSpecificationsElectricalDCACInputvoltage10–36Volts8–24VoltsInputpower6W6VAInputfrequencyN/A47–63HzEnvironmentalOperatingtemperature0°Cto+60°CStoragetemperature–40°Cto+85°CRelativehumidity10–95%non-condensingProtectionIP30FunctionalityStandardsIEEE802.
3ProcesstypeStore-and-ForwardPortsCoppertwisted-pairFibre1300nmNumberofports8or40,1or2Interface10BASE-T/100BASE-TX100BASE-FX10/100Mbps100MbpsAuto-negotiatesdatarateandflowcontrolConnectorsShieldedRJ-45MultimodeSCorSTorsingle-modeSCSegmentlength100m(max)2km(max)multimode,opticalbudgetis13dB15km(max)single-mode,opticalbudgetis19dBLEDindicatorsLink—GreenGreen—100MbpslinkPower—GreenFlashing—ActivityYellow—100MbpsFlashing—ActivityLoopdetect—RedFlowcontrolHalf-duplex(backpressure)Full-duplex(PAUSE)Aging215to322secondsFebruary2007TD000500-0DIPage4ElectromagneticCompatibilityStandardTestMethodDescriptionTestLevelsEN55024EN61000-4-2ElectrostaticDischarge6kVContactEN55024EN61000-4-3Radiatedimmunity10V/m,80MHzto1GHzEN55024EN61000-4-4FastTransientBurst1kVClamp&2kVDirectEN55024EN61000-4-5VoltageSurge1kVLtoL&2kVLtoEarthEN55024EN61000-4-6ConductedImmunity10Volts(rms)EN55024EN61000-4-11VoltageDips&Interruptions1LineCycle,1to5sec.
@100%dipEN55022CISPR22RadiatedEmissionsClassAEN55022CISPR22ConductedEmissionsClassBCFR47,Part15ANSIC63.
4RadiatedEmissionsClassAOrderingInformationCopperOnlyModelDescriptionEIS8-100TEight-port10BASE-T/100BASE-TXswitchFibreandCopperEIS5-100T/FCFour-port100BASE-TX/one-port100BASE-FX(multimode)switchw/SCconnectorsEIS5-100T/FTFour-port100BASE-TX/one-port100BASE-FX(multimode)switchw/STconnectorsEIS5-100T/FCSFour-port100BASE-TX/one-port100BASE-FX(single-mode)switchw/SCconnectorsEIS6-100T/FCFour-port100BASE-TX/two-port100BASE-FX(multimode)switchw/SCconnectorsEIS6-100T/FTFour-port100BASE-TX/two-port100BASE-FX(multimode)switchw/STconnectorsEIS6-100T/FCSFour-port100BASE-TX/two-port100BASE-FX(single-mode)switchw/SCconnectorsAccessoriesModelDescriptionAI-XFMRWall-mountplug-intransformer120VAC(nom)input/24VAC(nom)outputAI-XFMR-EWall-mountplug-intransformer230VAC(nom)input/24VAC(nom)outputContemporaryControlSystems,Inc.
2431CurtissStreetDownersGrove,Illinois60515USATelephone(630)963-7070Fax(630)963-0109ContemporaryControls,ARCControl,ARCDETECT,EXTEND-A-BUSandCTRLinkareregisteredtrademarksortrademarksofContemporaryControlSystems,Inc.
Specificationsaresubjecttochangewithoutnotice.
Otherproductnamesmaybetrademarksorregisteredtrademarksoftheirrespectivecompanies.
Copyright2007ContemporaryControlSystems,Inc.
DataSheetEISSerieswww.
ccontrols.
com

#推荐# cmivps:全场7折,香港不限流量VPS,支持Windows系统

cmivps香港VPS带来了3个新消息:(1)双向流量改为单向流量,相当于流量间接扩大一倍;(2)Hong Kong 2T、Hong Kong 3T、Hong Kong 无限流量,这三款VPS开始支持Windows系统,如果需要中文版Windows系统请下单付款完成之后发ticket要求官方更改即可;(3)全场7折年付、8折月付优惠,优惠码有效期一个月!官方网站:https://www.cmivp...

易探云:香港大带宽/大内存物理机服务器550元;20Mbps带宽!三网BGP线路

易探云怎么样?易探云隶属于纯乐电商旗下网络服务品牌,香港NTT Communications合作伙伴,YiTanCloud Limited旗下合作云计算品牌,数十年云计算行业经验。发展至今,我们已凝聚起港内领先的开发和运维团队,积累起4年市场服务经验,提供电话热线/在线咨询/服务单系统等多种沟通渠道,7*24不间断服务,3分钟快速响应。目前,易探云提供香港大带宽20Mbps、16G DDR3内存、...

美国高防云服务器 1核 1G 10M 38元/月 百纵科技

百纵科技:美国云服务器活动重磅来袭,洛杉矶C3机房 带金盾高防,会员后台可自助管理防火墙,添加黑白名单 CC策略开启低中高.CPU全系列E52680v3 DDR4内存 三星固态盘列阵。另有高防清洗!百纵科技官网:https://www.baizon.cn/联系QQ:3005827206美国洛杉矶 CN2 云服务器CPU内存带宽数据盘防御价格活动活动地址1核1G10M10G10G38/月续费同价点击...

easypanel为你推荐
linux主机linux主机与Windows主机的区别?谢谢asp主机sulzer主机类型有哪些网站域名域名和网址有什么区别ip代理地址代理IP是什么海外域名什么叫海外域名?云服务器租用云服务器租用需要注意哪些方面免备案虚拟空间备案退两次了。哪里有免备案空间虚拟主机用?香港虚拟主机想买一个香港虚拟主机,大家推荐一下吧apache虚拟主机Apache跟虚拟主机有什么关系?虚拟主机mysql虚拟主机支持mysql数据库,还需要额外购买mysql吗?
重庆服务器租用 什么是域名地址 a2hosting linkcloud 20g硬盘 全站静态化 idc资讯 腾讯实名认证中心 南通服务器 广州服务器 中国电信测速网 美国免费空间 息壤代理 酷番云 免费dns解析 空间登陆首页 shuang12 华为云建站 电信宽带测速软件 腾讯网盘 更多